The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
본 논문에서는 전자기 적합성(EMC) 테스트를 위해 RTC(반향 TEM 셀)의 작동 주파수 대역을 확장하는 방법을 제시합니다. RTC의 작동 주파수 대역을 확장하기 위해 본 논문에서는 고체 격막 대신 와이어 격막을 셀 내부에 배치합니다. TEM 셀 작동을 위한 최대 사용 가능 주파수(MUF)와 와이어 격막을 사용한 잔향실 작동을 위한 최저 사용 가능 주파수(LUF)를 연구하고 기존 고체 격막과 비교합니다. RTC 내부의 E 전계 강도가 측정되고 평가됩니다. 측정 결과, Wire Septum을 적용한 RTC는 TEM 모드에서는 Solid Septum을 적용한 RTC와 비슷한 MUF를 나타내지만, 잔향 모드에서는 훨씬 낮은 LUF를 나타내어 RTC의 동작 주파수 대역을 다음과 같이 확장할 수 있음을 증명합니다. 와이어 격막.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
부
Hye-Kwang KIM, Jung-Hoon KIM, Eugene RHEE, Sung-Il YANG, "A Method of Expanding Operating Frequency Band in a Reverberating TEM Cell by Using a Wire Septum" in IEICE TRANSACTIONS on Communications,
vol. E93-B, no. 11, pp. 3066-3071, November 2010, doi: 10.1587/transcom.E93.B.3066.
Abstract: This paper presents a method of expanding the operating frequency band of a Reverberating TEM Cell (RTC) for electromagnetic compatibility (EMC) testing. To expand the operating frequency band of an RTC, this paper places a wire septum inside the cell instead of a solid septum. The maximum usable frequency (MUF) for TEM cell operation and the lowest usable frequency (LUF) for reverberating chamber operation with the wire septum are studied and compared with a conventional solid septum. The E field strengths inside the RTC are measured and evaluated. The measurement results show that the RTC with the wire septum have similar MUF to the RTC with a solid septum at TEM mode, but have much lower LUF at a reverberating mode, which proves that the operating frequency band of the RTC can be expanded by using the wire septum.
URL: https://global.ieice.org/en_transactions/communications/10.1587/transcom.E93.B.3066/_p
부
@ARTICLE{e93-b_11_3066,
author={Hye-Kwang KIM, Jung-Hoon KIM, Eugene RHEE, Sung-Il YANG, },
journal={IEICE TRANSACTIONS on Communications},
title={A Method of Expanding Operating Frequency Band in a Reverberating TEM Cell by Using a Wire Septum},
year={2010},
volume={E93-B},
number={11},
pages={3066-3071},
abstract={This paper presents a method of expanding the operating frequency band of a Reverberating TEM Cell (RTC) for electromagnetic compatibility (EMC) testing. To expand the operating frequency band of an RTC, this paper places a wire septum inside the cell instead of a solid septum. The maximum usable frequency (MUF) for TEM cell operation and the lowest usable frequency (LUF) for reverberating chamber operation with the wire septum are studied and compared with a conventional solid septum. The E field strengths inside the RTC are measured and evaluated. The measurement results show that the RTC with the wire septum have similar MUF to the RTC with a solid septum at TEM mode, but have much lower LUF at a reverberating mode, which proves that the operating frequency band of the RTC can be expanded by using the wire septum.},
keywords={},
doi={10.1587/transcom.E93.B.3066},
ISSN={1745-1345},
month={November},}
부
TY - JOUR
TI - A Method of Expanding Operating Frequency Band in a Reverberating TEM Cell by Using a Wire Septum
T2 - IEICE TRANSACTIONS on Communications
SP - 3066
EP - 3071
AU - Hye-Kwang KIM
AU - Jung-Hoon KIM
AU - Eugene RHEE
AU - Sung-Il YANG
PY - 2010
DO - 10.1587/transcom.E93.B.3066
JO - IEICE TRANSACTIONS on Communications
SN - 1745-1345
VL - E93-B
IS - 11
JA - IEICE TRANSACTIONS on Communications
Y1 - November 2010
AB - This paper presents a method of expanding the operating frequency band of a Reverberating TEM Cell (RTC) for electromagnetic compatibility (EMC) testing. To expand the operating frequency band of an RTC, this paper places a wire septum inside the cell instead of a solid septum. The maximum usable frequency (MUF) for TEM cell operation and the lowest usable frequency (LUF) for reverberating chamber operation with the wire septum are studied and compared with a conventional solid septum. The E field strengths inside the RTC are measured and evaluated. The measurement results show that the RTC with the wire septum have similar MUF to the RTC with a solid septum at TEM mode, but have much lower LUF at a reverberating mode, which proves that the operating frequency band of the RTC can be expanded by using the wire septum.
ER -