The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
유기전자소자는 임플란트 센서에 적용 가능하다. 획득된 데이터의 노이즈는 슬라이딩 윈도우를 사용하여 스무딩하여 제거할 수 있습니다. 우리는 부드러움과 유사성(SSC)을 기반으로 창 크기 결정을 위한 새로운 기준을 개발했습니다. 평활화된 곡선은 원시 데이터에 잘 맞으며 충분히 평활합니다.
Kenichi SHIBATA
Yokohama National University
Takashi AMEMIYA
Yokohama National University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
부
Kenichi SHIBATA, Takashi AMEMIYA, "How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data" in IEICE TRANSACTIONS on Electronics,
vol. E102-C, no. 2, pp. 143-146, February 2019, doi: 10.1587/transele.2018OMS0003.
Abstract: Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.2018OMS0003/_p
부
@ARTICLE{e102-c_2_143,
author={Kenichi SHIBATA, Takashi AMEMIYA, },
journal={IEICE TRANSACTIONS on Electronics},
title={How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data},
year={2019},
volume={E102-C},
number={2},
pages={143-146},
abstract={Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.},
keywords={},
doi={10.1587/transele.2018OMS0003},
ISSN={1745-1353},
month={February},}
부
TY - JOUR
TI - How to Decide Window-Sizes of Smoothing Methods: A Goodness of Fit Criterion for Smoothing Oscillation Data
T2 - IEICE TRANSACTIONS on Electronics
SP - 143
EP - 146
AU - Kenichi SHIBATA
AU - Takashi AMEMIYA
PY - 2019
DO - 10.1587/transele.2018OMS0003
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E102-C
IS - 2
JA - IEICE TRANSACTIONS on Electronics
Y1 - February 2019
AB - Organic electronics devices can be applicable to implant sensors. The noises in the acquired data can be removed by smoothing using sliding windows. We developed a new criterion for window-size decision based on smoothness and similarity (SSC). The smoothed curve fits the raw data well and is sufficiently smooth.
ER -