The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
본 논문에서는 전기 접점의 비아킹 회로 차단 현상에 대한 실험 데이터를 제시합니다. 전기 접점 사이의 비발광 브리지인 다크 브리지는 비아킹 회로 차단에 효과적인 요소입니다. 전극의 위치를 정밀하게 제어하기 위해 캔틸레버 시스템의 설비를 구축하였습니다. 이 설비를 이용하여 접점 사이에 다크 브릿지를 만들고 이를 현미경 카메라 시스템으로 관찰하였다.
Hiroyuki ISHIDA
Tohoku Bunka Gakuen University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
부
Hiroyuki ISHIDA, "Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge" in IEICE TRANSACTIONS on Electronics,
vol. E103-C, no. 5, pp. 238-245, May 2020, doi: 10.1587/transele.2019ECP5028.
Abstract: In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.2019ECP5028/_p
부
@ARTICLE{e103-c_5_238,
author={Hiroyuki ISHIDA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge},
year={2020},
volume={E103-C},
number={5},
pages={238-245},
abstract={In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.},
keywords={},
doi={10.1587/transele.2019ECP5028},
ISSN={1745-1353},
month={May},}
부
TY - JOUR
TI - Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge
T2 - IEICE TRANSACTIONS on Electronics
SP - 238
EP - 245
AU - Hiroyuki ISHIDA
PY - 2020
DO - 10.1587/transele.2019ECP5028
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E103-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2020
AB - In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.
ER -