전기 접점은 일정한 속도로 분리되며 200V-450VDC/10A 저항 회로의 질소 또는 공기에서 차단 아크가 생성됩니다. 브레이크 아크는 자기 분출에 의해 소멸됩니다. 은 및 구리 접점 쌍의 아크 지속 시간은 각 공급 전압에 대해 조사됩니다. 다음 결과가 표시됩니다. 질소에서 Cu 접점의 아크 지속 시간은 가장 짧습니다. Cu 접점의 경우 공기 중 아크 체류 시간은 질소의 아크 체류 시간보다 상당히 길었습니다. Ag 접촉의 경우 질소의 아크 지속 시간은 공기의 아크 지속 시간과 거의 동일했습니다.
Akinori ISHIHARA
Shizuoka University
Junya SEKIKAWA
Shizuoka University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
부
Akinori ISHIHARA, Junya SEKIKAWA, "Arc Duration and Dwell Time of Break Arcs Magnetically Blown-out in Nitrogen or Air in a 450VDC/10A Resistive Circuit" in IEICE TRANSACTIONS on Electronics,
vol. E101-C, no. 9, pp. 699-702, September 2018, doi: 10.1587/transele.E101.C.699.
Abstract: Electrical contacts are separated at constant speed and break arcs are generated in nitrogen or air in a 200V-450VDC/10A resistive circuit. The break arcs are extinguished by magnetic blow-out. Arc duration for the silver and copper contact pairs is investigated for each supply voltage. Following results are shown. The arc duration for Cu contacts in nitrogen is the shortest. For Cu contacts, the arc dwell time in air was considerably longer than that of nitrogen. For Ag contacts, the arc duration in nitrogen was almost the same as that in air.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E101.C.699/_p
부
@ARTICLE{e101-c_9_699,
author={Akinori ISHIHARA, Junya SEKIKAWA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Arc Duration and Dwell Time of Break Arcs Magnetically Blown-out in Nitrogen or Air in a 450VDC/10A Resistive Circuit},
year={2018},
volume={E101-C},
number={9},
pages={699-702},
abstract={Electrical contacts are separated at constant speed and break arcs are generated in nitrogen or air in a 200V-450VDC/10A resistive circuit. The break arcs are extinguished by magnetic blow-out. Arc duration for the silver and copper contact pairs is investigated for each supply voltage. Following results are shown. The arc duration for Cu contacts in nitrogen is the shortest. For Cu contacts, the arc dwell time in air was considerably longer than that of nitrogen. For Ag contacts, the arc duration in nitrogen was almost the same as that in air.},
keywords={},
doi={10.1587/transele.E101.C.699},
ISSN={1745-1353},
month={September},}
부
TY - JOUR
TI - Arc Duration and Dwell Time of Break Arcs Magnetically Blown-out in Nitrogen or Air in a 450VDC/10A Resistive Circuit
T2 - IEICE TRANSACTIONS on Electronics
SP - 699
EP - 702
AU - Akinori ISHIHARA
AU - Junya SEKIKAWA
PY - 2018
DO - 10.1587/transele.E101.C.699
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E101-C
IS - 9
JA - IEICE TRANSACTIONS on Electronics
Y1 - September 2018
AB - Electrical contacts are separated at constant speed and break arcs are generated in nitrogen or air in a 200V-450VDC/10A resistive circuit. The break arcs are extinguished by magnetic blow-out. Arc duration for the silver and copper contact pairs is investigated for each supply voltage. Following results are shown. The arc duration for Cu contacts in nitrogen is the shortest. For Cu contacts, the arc dwell time in air was considerably longer than that of nitrogen. For Ag contacts, the arc duration in nitrogen was almost the same as that in air.
ER -