The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
구강 내 타액 pH와 조직 온도를 동시에 모니터링하기 위해 의치상 유형의 새로운 센서 시스템이 개발되었습니다. 본 문서에서는 모니터링 시스템, 센서 장치 및 센서 구성의 기본 구성 요소를 보여줍니다. 센서 장치는 IrO로 구성됩니다.2 구강 내에 단단히 고정된 의치상에 전극과 서미스터 회로를 이식한 것입니다. PFM-FM 원격계 시스템을 통해 신호가 전송되며, 직장, 수면, 운동 중에도 노인들의 일상 행동에 제약을 받지 않고 건강 관리에 사용할 수 있습니다. 센서 시스템의 기본 특성과 지속적으로 모니터링되는 생리학적 데이터에 관한 일부 결과는 예비 실험을 통해 얻어졌습니다. 전체 시스템의 가용성과 모니터링 방법이 논의되었습니다.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
부
Haruyuki MINAMITANI, Yoichiro SUZUKI, Atsuhiko IIJIMA, Tomokazu NAGAO, "A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity" in IEICE TRANSACTIONS on Information,
vol. E85-D, no. 1, pp. 22-29, January 2002, doi: .
Abstract: A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.
URL: https://global.ieice.org/en_transactions/information/10.1587/e85-d_1_22/_p
부
@ARTICLE{e85-d_1_22,
author={Haruyuki MINAMITANI, Yoichiro SUZUKI, Atsuhiko IIJIMA, Tomokazu NAGAO, },
journal={IEICE TRANSACTIONS on Information},
title={A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity},
year={2002},
volume={E85-D},
number={1},
pages={22-29},
abstract={A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.},
keywords={},
doi={},
ISSN={},
month={January},}
부
TY - JOUR
TI - A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity
T2 - IEICE TRANSACTIONS on Information
SP - 22
EP - 29
AU - Haruyuki MINAMITANI
AU - Yoichiro SUZUKI
AU - Atsuhiko IIJIMA
AU - Tomokazu NAGAO
PY - 2002
DO -
JO - IEICE TRANSACTIONS on Information
SN -
VL - E85-D
IS - 1
JA - IEICE TRANSACTIONS on Information
Y1 - January 2002
AB - A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.
ER -